IBM 6578 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
011-013-XXX
011-014-XXXSerial port Control
Signal/Loopback test failure
1. System board
011-015-XXXSerial port External Loopback
failure
1. Wrap plug
2. System board
011-027-XXXSerial port Configuration/Setup
error
1. Run Setup, enable port
2. Flash the system
3. System board
011-03X-XXX
011-04X-XXXSerial port failure
1. System board
011-195-XXXSerial port Test aborted by user
1. Information
2. Re-start the test, if necessary
011-196-XXXSerial port test halt, error
threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
011-197-XXXSerial port test warning
1. Make sure the component that is called out is
connected and/or enabled
2. Re-run test
3. Component that is called out in warning statement
4. Component under test
011-198-XXXSerial port test aborted
1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problems section
011-199-XXXSerial port test failed, cause
unknown
1. Go to the Undetermined problems section
2. Flash the system and re-test
3. Replace component under function test
011-2XX-XXXSerial port signal failure
1. External serial device
2. System board
014-000-XXXParallel port Interface Test Passed
1. No action
014-001-XXXParallel port Presence
1. Remove external parallel device, if present
2. Run setup, enable port
3. System board
014-002-XXX
014-003-XXXParallel port Timeout/Parity error
1. System board
8 Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,
6649