IBM 6578 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
015-015-XXXUSB port External Loopback
failure
1. Remove USB device(s) and re-test
2. System board
015-027-XXXUSB port Configuration/Setup
error
1. Flash the system
2. System board
015-032-XXXUSB port Device Controller failure
1. System board
015-034-XXXUSB port bufferallocation failure
1. Reboot the system
2. Flash the system
3. Run memory test
4. System board
015-035-XXXUSB port Reset condition detected
1. Remove USB device(s) and re-test
2. System board
015-036-XXXUSB port Register error
1. System board
015-040-XXXUSB port IRQ failure
1. Run setup and check for conflicts
2. Flash the system
3. System board
015-195-XXXUSB port Test aborted by user
1. Information
2. Re-start the test, if necessary
015-196-XXXUSB port test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
015-197-XXXUSB port test warning
1. Make sure the component that is called out is
connected and/or enabled
2. Re-run test
3. Component that is called out in warning statement
4. Component under test
015-198-XXXUSB port test aborted
1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problems section
015-199-XXXUSB port test failed, cause
unknown
1. Go to the Undetermined problems section
2. Flash the system and re-test
3. Replace component under function test
018-000-XXXPCI Card Test Passed
1. No action
10 Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,
6649