IBM 6578 Personal Computer User Manual


 
Message Failure Found Recommended Actions
2xx-2y A memory error was detected in
DIMM/RIMM socket Y
Replace the DIMM/RIMM in the
socket identified by the last digit
of the error code.
Re-run the test.
If the same error code occurs
again, replace the system board
or where memory is on the
processor card, replace the
processor card.
Corrupt BIOS Information in BIOS is not as
expected.
Not able to find expected DMI
information from BIOS.
Memory controller chipset
vendor ID does not match
expected value.
Reflash the BIOS.
Perform boot block recovery.
Replace the system board.
Test aborted by user User stopped test. Restart test.
Note: Y is the SIMM/DIMM/RIMM socket number. Use the System Board
Layout section in the latest Hardware Maintenance Manual (HMM) to
reference the memory sockets.
Setup Utility program
Attention
A customized setup configuration (other than default settings) might
exist on the computer you are servicing. Running the Setup Utility
program might alter those settings. Note the current configuration
settings and verify that the settings are in place when service is
complete.
The Setup Utility (configuration) program is stored in the permanent memory
of the computer. This program includes settings for the following:
v System Summary
v Product Data
v Devices and I/O Ports
v Start Options
v Date and Time
v System Security
Chapter 2. Types 6568/6569/6648/6649 41