Diagnostic Error Code FRU/Action
018-0XX-XXXPCI Card Failure
1. Riser card, if installed
2. System board
018-195-XXXPCI Card Test aborted by user
1. PCI card
2. Information
3. Re-start the test, if necessary
018-196-XXXPCI Card test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
018-197-XXXPCI Card test warning
1. Make sure the component that is called out is
connected and/or enabled
2. Re-run test
3. Component that is called out in warning statement
4. Component under test
018-198-XXXPCI Card test aborted
1. Make sure the component that is called out is
connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problems section
018-199-XXXPCI Card test failed, cause
unknown
1. Go to the Undetermined problems section
2. Flash the system and re-test
3. Replace component under function test
018-250-XXXPCI Card Services error
1. PCI card
2. Riser card, if installed
3. System board
020-000-XXXPCI Interface Test Passed
1. No action
020-0XX-XXXPCI Interface error
1. PCI card
2. Riser card, if installed
3. System board
020-195-XXXPCI Test aborted by user
1. Information
2. Re-start the test, if necessary
020-196-XXXPCI test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
Chapter 1. IBM PC Enhanced Diagnostics error codes 11