Chapter 1. IBM PC Enhanced Diagnostics error codes
Refer to the following Diagnostic Error Codes when using the IBM PC
Enhanced Diagnostics test. See the ″Diagnostic and test information″ section
for the specific model for information about the IBM PC Enhanced
Diagnostics program.
In the following index, X can represent any number.
Diagnostic Error Code FRU/Action
000-000-XXX BIOS Test Passed
1. No action
000-002-XXXBIOS Timeout
1. Flash the system
2. System board
000-024-XXXBIOS Addressing test failure
1. Flash the system
2. System board
000-025-XXXBIOS Checksum Value error
1. Flash the system
2. Boot block
3. System board
000-026-XXXFLASH data error
1. Flash the system
2. Boot block
3. System board
000-027-XXXBIOS Configuration/Setup error
1. Run Setup
2. Flash the system
3. Boot block
4. System board
000-034-XXXBIOS Buffer Allocation failure
1. Reboot the system
2. Flash the system
3. Run memory test
4. System board
000-035-XXXBIOS Reset Condition detected
1. Flash the system
2. System board
000-036-XXXBIOS Register error
1. Flash the system
2. Boot block
3. System board
© Copyright IBM Corp. 2000 1