IBM 6648 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
020-197-XXXPCI test warning
1. Make sure the component that is called out is
connected and/or enabled
2. Re-run test
3. Component that is called out in warning statement
4. Component under test
020-198-XXXPCI test aborted
1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problems section
020-199-XXXPCI test failed, cause unknown
1. Go to the Undetermined problems section
2. Flash the system and re-test
3. Replace component under function test
020-262-XXX
PCI system error
1. PCI card
2. Riser card, if installed
3. System board
025-000-XXX
IDE interface Test Passed
1. No action
025-00X-XXX
025-01X-XXXIDE interface failure
1. IDE signal cable
2. Check power supply
3. IDE device
4. System board
025-027-XXXIDE interface Configuration/Setup
error
1. IDE signal cable
2. Flash the system
3. IDE device
4. System board
025-02X-XXX
025-03X-XXX
025-04X-XXXIDE Interface failure
1. IDE signal cable
2. Check power supply
3. IDE device
4. System board
025-195-XXXIDE interface Test aborted by user
1. Information
2. Re-start the test, if necessary
025-196-XXXIDE interface test halt, error
threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
12 Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,
6649