IBM 71455DU Server User Manual


 
Lever closed
Lever fully
open
Note: Two of the microprocessor sockets are mounted on the microprocessor
board with the microprocessor-release lever on the opposite side. These
sockets are rotated 180° on the microprocessor board. Be sure to verify the
orientation of the socket before installing the microprocessor.
8. Touch the static-protective package that contains the new microprocessor to
any unpainted metal surface on the outside of the server; then, remove the
microprocessor from the package.
Attention: To avoid bending the pins on the microprocessor, do not use
excessive force when pressing it into the socket
9. Position the microprocessor over the microprocessor socket and carefully
press the microprocessor into the socket.
Microprocessor
orientation indicator
Microprocessor-
release lever
Microprocessor
connector
Microprocessor
10. Close the microprocessor-release lever to secure the microprocessor.
11. Open the heat-sink retaining clip:
a. Press down on the center of the heat-sink retaining clip. This will cause the
clip to flex and release it from the tabs on the heat-sink socket.
b. Lift the heat-sink retaining clip to the fully open position (approximately
135° angle).
12.
Remove the heat sink from its package and remove the cover from the bottom
of the heat sink.
13. Remove the release liner and orient the heat sink above the microprocessor;
then, press the heat sink into place and close the heat-sink release lever.
14. If you have other microprocessors to install, do so now by repeating steps 5
through 13.
15. Install the air baffle in the microprocessor tray.
16. Reinstall the microprocessor tray in the server:
46 IBM System x3950 Type 8878 and System x3950 E Type 8879: User’s Guide