IBM 8301 Computer Hardware User Manual


 
Diagnostic
Error
Code
FRU/Action
018-195-XXX
PCI
Card
Test
aborted
by
user
1.
PCI
card
2.
Information
3.
Re-start
the
test,
if
necessary
018-196-XXX
PCI
Card
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
018-197-XXX
PCI
Card
test
warning
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled
2.
Re-run
test
3.
Component
that
is
called
out
in
warning
statement
4.
Component
under
test
018-198-XXX
PCI
Card
test
aborted
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled
2.
Flash
the
system
and
re-test
3.
Go
to
the
Undetermined
problems
section
018-199-XXX
PCI
Card
test
failed,
cause
unknown
1.
Go
to
the
Undetermined
problems
section
2.
Flash
the
system
and
re-test
3.
Replace
component
under
function
test
018-250-XXX
PCI
Card
Services
error
1.
PCI
card
2.
Riser
card,
if
installed
3.
System
board
020-000-XXX
PCI
Interface
Test
Passed
1.
No
action
020-0XX-XXX
PCI
Interface
error
1.
PCI
card
2.
Riser
card,
if
installed
3.
System
board
020-195-XXX
PCI
Test
aborted
by
user
1.
Information
2.
Re-start
the
test,
if
necessary
020-196-XXX
PCI
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
020-197-XXX
PCI
test
warning
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled
2.
Re-run
test
3.
Component
that
is
called
out
in
warning
statement
4.
Component
under
test
020-198-XXX
PCI
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled
2.
Flash
the
system
and
re-test
3.
Go
to
the
Undetermined
problems
section
98
Hardware
Maintenance
Manual