IBM 8301 Computer Hardware User Manual


 
Diagnostic
error
codes
Refer
to
the
following
diagnostic
error
codes
when
using
the
diagnostic
tests.
See
Diagnostics
on
page
23
for
the
specific
type
for
information
about
the
Diagnostic
programs.
In
the
following
index,
X
can
represent
any
number.
Diagnostic
Error
Code
FRU/Action
000-000-XXX
BIOS
Test
Passed
1.
No
action
000-002-XXX
BIOS
Timeout
1.
Flash
the
system
2.
System
board
000-024-XXX
BIOS
Addressing
test
failure
1.
Flash
the
system
2.
System
board
000-025-XXX
BIOS
Checksum
Value
error
1.
Flash
the
system
2.
Boot
block
3.
System
board
000-026-XXX
FLASH
data
error
1.
Flash
the
system
2.
Boot
block
3.
System
board
000-027-XXX
BIOS
Configuration/Setup
error
1.
Run
Setup
2.
Flash
the
system
3.
Boot
block
4.
System
board
000-034-XXX
BIOS
Buffer
Allocation
failure
1.
Reboot
the
system
2.
Flash
the
system
3.
Run
memory
test
4.
System
board
000-035-XXX
BIOS
Reset
Condition
detected
1.
Flash
the
system
2.
System
board
000-036-XXX
BIOS
Register
error
1.
Flash
the
system
2.
Boot
block
3.
System
board
000-038-XXX
BIOS
Extension
failure
1.
Flash
the
system
2.
Adapter
card
3.
System
board
000-039-XXX
BIOS
DMI
data
error
1.
Flash
the
system
2.
System
board
000-195-XXX
BIOS
Test
aborted
by
user
1.
Information
2.
Re-start
the
test,
if
necessary
000-196-XXX
BIOS
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
Chapter
7.
Symptom-to-FRU
Index
89