IBM 8301 Computer Hardware User Manual


 
Diagnostic
Error
Code
FRU/Action
170-195-XXX
Voltage
Sensor(s)
Test
aborted
by
user
1.
Information
2.
Re-start
the
test,
if
necessary
170-196-XXX
Voltage
Sensor(s)
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
170-197-XXX
Voltage
Sensor(s)
test
warning
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled
2.
Re-run
test
3.
Component
that
is
called
out
in
warning
statement
4.
Component
under
test
170-198-XXX
Voltage
Sensor(s)
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled
2.
Flash
the
system
and
re-test
3.
Go
to
the
Undetermined
problems
section
170-199-XXX
Voltage
Sensor(s)
test
failed,
cause
unknown
1.
Go
to
the
Undetermined
problems
section
2.
Flash
the
system
and
re-test
3.
Replace
component
under
function
test
170-250-XXX
170-251-XXX
Voltage
Sensor(s)
Voltage
limit
error
1.
Power
supply
2.
System
board
170-254-XXX
Voltage
Sensor(s)
Voltage
Regulator
Module
error
1.
Voltage
Regulator
Module
(VRM)
2.
Microprocessor
3.
System
board
175-000-XXX
Thermal
Sensor(s)
Test
Passed
1.
No
action
175-0XX-XXX
Thermal
Sensor(s)
failure
1.
Flash
system
2.
System
board
175-195-XXX
Thermal
Sensor(s)
Test
aborted
by
user
1.
Information
2.
Re-start
the
test,
if
necessary
175-196-XXX
Thermal
Sensor(s)
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
175-197-XXX
Thermal
Sensor(s)
test
warning
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled
2.
Re-run
test
3.
Component
that
is
called
out
in
warning
statement
4.
Component
under
test
175-198-XXX
Thermal
Sensor(s)
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled
2.
Flash
the
system
and
re-test
3.
Go
to
Undetermined
problems
section
104
Hardware
Maintenance
Manual