IBM 8301 Computer Hardware User Manual


 
POST
Error
Code
FRU/Action
6XX
Not
listed
above
1.
Diskette
Drive
2.
System
Board
3.
Riser
card
4.
External
Drive
Adapter
5.
Diskette
Drive
Cable
6.
Power
Supply
762
Math
coprocessor
configuration
error
1.
Run
Setup
2.
Processor
3.
System
Board
7XX
Not
listed
above
1.
Processor
2.
System
Board
962
Parallel
port
configuration
error
1.
Run
Configuration
2.
Parallel
Adapter
(if
installed)
3.
System
Board
9XX
1.
Printer
2.
System
Board
1047
1.
16-Bit
AT
Fast
SCSI
Adapter
107X
Check
SCSI
terminator
installation
1.
Check
SCSI
terminator
installation
2.
SCSI
Cable
3.
SCSI
Terminator
4.
SCSI
Device
5.
SCSI
Adapter
1101
Serial
connector
error,
possible
system
board
failure
1.
Run
Enhanced
Diagnostics
1101,
1102,
1106,
1108,
1109
1.
System
Board
2.
Any
Serial
Device
1107
1.
Communications
Cable
2.
System
Board
1102
Card
selected
feedback
error
1.
Run
Enhanced
Diagnostics
1103
Port
fails
register
check
1.
Run
Enhanced
Diagnostics
2.
System
Board
1106
Serial
option
cannot
be
turned
off
1.
Run
Enhanced
Diagnostics
2.
System
Board
1107
1.
Serial
Device
Cable
2.
System
Board
1110
Register
test
failed
1.
Run
Enhanced
Diagnostics
2.
System
Board
1116
Interrupt
error
1.
Run
Enhanced
Diagnostics
114
Hardware
Maintenance
Manual