IBM 8301 Computer Hardware User Manual


 
Diagnostic
Error
Code
FRU/Action
001-301-XXX
System
RTC
Century
byte
error
1.
Flash
the
system
2.
System
board
005-000-XXX
Video
Test
Passed
1.
No
action
005-00X-XXX
Video
error
1.
Video
card,
if
installed
2.
System
board
005-010-XXX
005-011-XXX
005-012-XXX
005-013-XXX
Video
Signal
failure
1.
Video
card,
if
installed
2.
System
board
005-016-XXX
Video
Simple
Pattern
test
failure
1.
Video
Ram
2.
Video
card,
if
installed
3.
System
board
005-024-XXX
Video
Addressing
test
failure
1.
Video
card,
if
installed
2.
System
board
005-025-XXX
Video
Checksum
Value
error
1.
Video
card,
if
installed
2.
System
board
005-027-XXX
Video
Configuration/Setup
error
1.
Run
Setup
2.
Video
drivers
update
3.
Video
card,
if
installed
4.
System
board
005-031-XXX
Video
Device
Cable
failure
1.
Video
cable
2.
Monitor
3.
Video
card,
if
installed
4.
System
board
005-032-XXX
Video
Device
Controller
failure
1.
Video
card,
if
installed
2.
System
board
005-036-XXX
Video
Register
error
1.
Video
card,
if
installed
2.
System
board
005-038-XXX
System
BIOS
extension
failure
1.
Video
card,
if
installed
2.
System
board
005-040-XXX
Video
IRQ
failure
1.
Video
card,
if
installed
2.
System
board
005-195-XXX
Video
Test
aborted
by
user
1.
Information
2.
Re-start
the
test,
if
necessary
005-196-XXX
Video
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
Chapter
7.
Symptom-to-FRU
Index