IBM B50 Printer User Manual


 
Error Code Function
/Description
Repair Action/Possible Failing FRU
25A80203 Unable to expand
target partition while
writing VPD data.
Refer to 25A80xxx.
25A80210 Setenv/$Setenv
parameter error -
name contains a null
character.
Refer to 25A80xxx.
25A80211 Setenv/$Setenv
parameter error -
value contains a null
character.
Refer to 25A80xxx.
25A80998 NVRAMRC script
evaluation error -
command line
execution error
Execution of a command line within the nvram
configuration variable “nvramrc” (script) resulted in a
“throw” being executed. This script can be modified by
the system firmware SMS utilities, the operating
system, PCI adapter rom code or utility, or an operator
(via the open firmware script editing command nvedit).
It may not be possible to resolve the problem without a
detailed analysis of the nvram script, the current
system configuration, and device tree contents.
1. The problem can be caused by a SCSI
adapter,whose SCSI bus ID has been changed
from the default setting, no longer appearing in the
system. This can be caused either by removing a
SCSI adapter, or a problem with a SCSI adapter.
a. Select the SCSI ID utility from the SMS
menu(s).
1) Verify the list of SCSI controllers/adapters.
If the list is not correct, suspect a problem
with the adapter(s) installed but not listed.
2) Select the option to save the configuration
information.
3) Restart the system.
b. If the problem persists, boot the operating
system and verify the SCSI bus IDs of any
installed/available SCSI controllers (change as
necessary), and restart the system.
2. Contact your service support representative for
further assistance.
25A80999 NVRAMRC script
evaluation error -
stack unbalanced on
completion.
This is a firmware debug environment error. There is
no user action or FRU replacement for this error.
3-8 7046 Model B50 Service Guide