44 Intel® Server System SR2500AL User’s Guide
Figure 33. Installing the Large Air Baffle
3. Install the server system cover. For instructions, see “Installing the Server System
Cover”.
4. Plug all peripheral devices and the AC power cable(s) into the server.
Installing and Removing a Hot-swap Hard Drive
Up to six hot-swap SAS or SATA drives can be installed.
Cautions: If you install less than six drives or devices, empty drive bays must be occupied by
carriers with baffles to maintain proper system cooling.
To avoid possible damage to your server system, do not use older style drive carriers.
Note: The server system does not support all hard drives. See “Server System References“ for
an Internet link to a list of supported hardware.
Installing a SAS or SATA Hot-swap Hard Disk Drive
1. Remove the front bezel if it is installed. For instructions, see “Removing the Front
Bezel”.
2. Open the latch at the front of the hard drive carrier. See letter "A" in the figure
below.
TP02134