Power Supply Connector
When used with an SSI ATX-compliant power supply that supports remote power
on/off, the motherboard can turn off the system power through software control.
To enable soft-off control in software, advanced power management must be
enabled in the Setup program and in the operating system. When the system BIOS
receives the correct APM command from the operating system, the BIOS turns off
power to the computer.
With soft-off enabled, if power to the computer is interrupted by a power outage or a
disconnected power cord, when power resumes, the computer returns to the power
state it was in before power was interrupted (on or off).
Table 70: Power Supply Connector
Pin Signal Name
1 +3.3 V
2 +3.3 V
3 Ground
4 +5 V
5 Ground
6 +5 V
7 Ground
8 PWRGD (Power Good)
9 +5 VSB (Standby)
10 +12 V
11 +3.3 V
12 -12 V
13 Ground
14 PS-ON# (power supply remote on/off control)
15 Ground
16 Ground
17 Ground
18 -5 V
19 Ground
20 Not connected
21 +5
22 +5
23 +5
24 Ground
Table 71: PS/2 Keyboard/Mouse Connectors
Pin Signal Name
1 Data
2 No connect
3 Ground
4 +5 V (fused)
5 Clock
6 No connect
Table 72: Stacked USB Connectors
Pin Signal Name
1 +5 V (fused)