94 Intermec EasyCoder PF4i Compact Industrial—User’s Guide (Fingerprint)
Chapter 10—Troubleshooting
Printer crash Off See note 3 and 9
Printer turned off Off
Maintenance Off Set when upgrading
Power supply Over tem-
perature
Off 1718
Note 1: This is only applicable for printers equipped with an EasyLAN interface.
Note 2: A printer that is equipped with an EasyLAN interface, but is not connected to
a network, will have a blinking IRI. To avoid this, the user can set “IP SELECTION” to
“MANUAL” and “IP ADDRESS” to “0.0.0.0”. This will indicate that the user does not
regard the lack of network connection as an error.
Note 3: No trap can be sent when this error/event occurs.
Note 4: This error indicates that the printer has not received an IP address. It is only
applicable for printers with IP SELECTION set to DHCP and/or BOOTP.
Note 5: In the Direct Protocol, the user can enable error handling for specifi c errors using
the ERROR statement. When errors added to the built-in error handling occur, this
event will be set. The text included in the snmp trap is the standard text corresponding to
the error.
Note 6: If an error occurs in the Fingerpruint immediate mode, for example “out of
paper” when the print key is pressed, this event will be set.
Note 7: If an application is started but does not execute, the IRI will blink. This will
occur for example if there is a syntax error in the loaded program fi le.
This is useful when a printer has an AUTOEXEC.BAT fi le (startup fi le) that is supposed
to run automatically.
Note 8: When execution is stopped with user break (SHIFT + PAUSE) or due to a
run-time error, the IRI shall be off. It will be set to on if the user changes mode to Direct
Protocol or runs an application.
If, however, the application program handles the user break (ON BREAK) or the run-
time error (ON ERROR GOTO), the IRI will not be affected. In this case, it is up to the
application to set the status.
Note 9: At most, but not all, printer crashes, the console is reset. This will make the IRI
go off.