114 Intermec EasyCoder PF4i Compact Industrial—User’s Guide (Fingerprint)
Chapter 12—Adjustments
LTS (Label Taken Sensor)
The sensitivity of the LTS may need to be adjusted according to ambi-
ent light conditions and refl ective characteristics of the back side of the
media. This is done in the Setup Mode (Print Defs/LTS), see Chapter 7.
You can also check that the LTS works properly.
The LTS setup options are only displayed if an optional label taken
sensor is installed in the printer.
LTS Adjust
Press <Enter>. A label is fed out. Remove the label and press <Enter>
again. A menu shows the sensitivity automatically selected by the fi rm-
ware and the range, in which the LTS will work. Press <Enter> again and
you will proceed to the LTS Test menu.
LTS Test
Press <Enter>. A label is fed out. Remove the label and a new label
should be fed out automatically. Repeat until you are sure the LTS works
properly. Then press <Enter> to stop and exit.
LTS Value
Press <Enter>. You can enter a new value in the range indicated in the
LTS Adjust menu (see above). Min/max values are in the range 0 to 10.