Juniper Networks J4350 Network Router User Manual


 
Figure 45: TIM516 Analog Telephony Interface Module
6
1
5
M
I
T
A
T
C
S
E
N
I
L
S
E
N
I
L
7
1
4
2
1
8
M
L
A
g
o
l
a
n
A
668300g
S
E
N
I
L
You can configure TIM516 lines as described in Table 43 on page 77.
Table 43: TIM516 Possible Port Configurations
Possible Analog Telephone (LINE) Line Configurations
Analog tip/ring devices such as single-line telephones with or without LED message-waiting indication
The TIM516 also provides the following features:
Three ringer loads, the ringer equivalency number for up to 2,000 ft (610 m),
for all 16 lines
Up to 16 simultaneously ringing lines
Type 1 caller ID and Type 2 caller ID for line lines
Ring voltage generation for a variety of international frequencies and cadences
For pinouts of cable connectors for the TIM516, see TIM516 Connector
Pinout on page 242.
To install or remove an Avaya VoIP module, see Replacing a PIM on page 172.
TIM516 LEDs indicate link status and activity. Table 44 on page 77 describes the
meaning of the LEDs.
Table 44: LEDs for TIM516
DescriptionStateColorLabel
Alarm. A TIM516 failure requires
monitoring or maintenance.
On steadilyRed
ALM
Active. A device connected to the
TIM516 is in use. This situation can
include a telephone that is off the
hook.
BlinkingYellow
ACT
Avaya VoIP Modules 77
Chapter 3: PIM and VoIP Module Overview