Kodak III Projector User Manual


 
KODAK EKTAGRAPHIC III Slide Projector 21
Maintenance
To ensure a long life and trouble-free operation for your projector:
Allow the air to flow freely around the projector.
Do not recirculate warm air.
Keep the projector dust free.
If your projector is chilled, bring it to room temperature before operating.
Projection Lamps Quartz-halogen 82 V projection lamps
Included: EXR, 300 W (35-hour lamp life at full lamp/medium-brightness)
Sampling of other lamps:
EXY (200 hours/less brightness)
EXW (15 hours/maximum brightness)
FHS (70 hours/medium brightness)
Use combinations of lamp brightness, plus half- and full-lamp settings to
approximate image brightness in multi-projector presentations.
Lamp Tips Projector operation on line voltages above 125 volts greatly
reduces the lamp life.
Unplug the projector before changing the lamp.
Allow for unrestricted flow of air to the exhaust vent to prolong
lamp life.
Gently wipe off any fingerprints with a soft cloth moistened with
rubbing alcohol.
Desired
Brightness
EKTAGRPAHIC III
Projector Lamp
Maximum EXW
High EXR
Medium FHS
Low EXY