Kodak III Projector User Manual


 
KODAK EKTAGRAPHIC III Slide Projector 27
Troubleshooting
Consult this guide before calling for service.
PROBLEM CAUSE CORRECTION
Projector does not operate No power to projector Plug power cord into suitable
electrical outlet. Set power
switch to Lamp.
No illumination on screen with slide in
projector gate
Power switch on Off or Fan Set switch to Lamp.
Lamp burned out Install new lamp or lamp module
Lamp not seated in socket Check lamp.
Slide not in proper focus on screen
focus.
Slide itself not sharp Examine slide for proper focus.
First slide in tray not properly Focus center of first slide.
Slide in different type of mount from
others
Focus manually.
Projection lens installed improperly Read and follow the instructions
for installing the lens.
Uneven edge-to-edge focus Slide itself is not sharp Examine slide.
Curved field lens used with glass,
plastic, or non-embosssed mounts
Try a flat field lens.
(See Choosing a Curved- or
Flat-Field Lens” on page 15.)
Curved field lens used for rear
projection
Use a flat field lens.
Autofocus motor runs continuously Glass slides in tray Turn off autofocus or use slides
with mounts other than glass.
Autofocus fails to operate Lamp performance Install new lamp and try
autofocus again.