Konica Minolta 5430 DL 5440 DL 5450 Printer User Manual


 
Main Unit Theory of Operation Fusing Section
2-105
II Composition/Operation
16.3.4 Fusing temperature control management
The appropriate type of temperature control is provided according to the machine status.
A. Conditions enabling shift to warm-up control
The Power Switch is turned ON.
A malfunction or media misfeed is reset.
The machine leaves the Power Save mode.
A door is closed.
B. Condition enabling shift to post-warm-up control
At the end of the warm-up control (no print request)
C. Conditions enabling shift to wait control
At the end of the warm-up control (no print request)
At the end of the post-print cycle control
D. Condition enabling shift to print control
A print request is accepted.
E. Condition enabling shift to post-print cycle control
At the end of the print control
F. Condition enabling shift to heater OFF control
A malfunction or media misfeed occurs.
A Power Save mode signal is received.
Reset
4138to2138e0
Warm-up controlHeater OFF
Post-warm-up control
Wait control
Print control
Post-print cycle control