Konica Minolta 5430 DL 5440 DL 5450 Printer User Manual


 
Main Unit Theory of Operation Toner Collecting Section
2-59
II Composition/Operation
10.3.6 Waste toner near-full condition detection
A waste toner near-full condition is detected using the output state of the Waste Toner
Full Sensor.
A waste toner full condition is detected based on the dot count.
The output value of the Waste Toner Full Sensor cannot be acquired during the AIDC
control (registration correction, gamma correction). During this period, therefore, the fol-
lowing control procedures are not performed: “waste toner status decision,” “waste toner
full condition reset decision,” “waste toner near-full condition reset decision,” and “waste
toner near-full condition detection control.”
A. Waste toner near-full condition detection control
A waste toner near-full condition is detected when the Waste Toner Full Sensor (PC11)
continuously outputs a voltage of a predetermined value or more for a predetermined
period of time or more.
At this time, a waste toner near-full condition warning is given on the panel.
To prevent false detection, a conveying screw is installed in the Waste Toner Box, ensur-
ing that waste toner is uniformly accumulated in the box.
Power source
Full condition
Waste toner /
Status decision
Full condition
detection
Full condition
reset decision
Near-full
condition reset
Near-full
condition
4138to2137e0
4138to2081c0
Waste Toner Full Sensor (PC11)
Box Tray
When the sensor is unblocked When the sensor is blocked
5430DL_5440DL_5450_TO_PDF.book 59 ページ 2005年4月12日 火曜日 午後4時49分