Konica Minolta 5430 DL 5440 DL 5450 Printer User Manual


 
Miscellaneous Main Unit Theory of Operation
2-124
II Composition/Operation
18.1.2 Control
A. LV Cooling Fan Motor (M10) control
<Full speed rotation conditions>
For the period of time that begins when the warm-up cycle is started and ends when a
predetermined period of time elapses after the warm-up cycle has been completed.
For the period of time that begins when the Intermediate Transport Motor (M3) is ener-
gized and ends when a predetermined period of time elapses after the motor is de-ener-
gized.
For the period of time during which the Fusing Pressure Roller deformation prevention
control is performed
<Half speed rotation conditions>
The motor runs at a half speed during any time other than above.
The motor runs at a half speed only when printing in monochrome mode without a
Duplex Option or optional Lower Feed Unit (magicolor 5440 DL/5450 only).
<Stop conditions>
Stopped in the Power Save mode. The motor is, however, run while the Ozone Ventilation
Fan Motor (M12) is running and stopped after the Ozone Ventilation Fan Motor (M12)
has been stopped. At this time, the motor is run at full speed for a predetermined period
of time after the Intermediate Transport Motor (M3) has been stopped and is run at half
speed thereafter.
<Forced stop condition>
A door is opened or a malfunction occurs, but not when an error occurs.
B. Fusing Cooling Fan Motor (M11) control
<Full speed rotation conditions>
For the period of time that begins when the Intermediate Transport Motor (M3) is
energized and ends when a predetermined period of time elapses after the motor is
de-energized.
<Half speed rotation conditions>
The motor runs at a half speed during any time other than above.
<Stop conditions>
Stopped in the Power Save mode. The motor is not, however, stopped for a predeter-
mined period of time after the Intermediate Transport Motor (M3) is de-energized.
<Forced stop condition>
A door is opened or a malfunction occurs, but not when an error occurs.
C. Ozone Ventilation Fan Motor (M12)
<Full speed rotation conditions>
At the start of a warm-up cycle
The Intermediate Transport Motor (M3) is energized.
<Stop conditions>
A predetermined period of time elapses after a warm-up cycle is completed
A predetermined period of time elapses after the Intermediate Transport Motor (M3) is
de-energized
Stopped in the Power Save mode. The motor is not, however, stopped for a predeter-
mined period of time after a predrive or a print cycle is completed.
<Forced stop condition>
A door is opened or a malfunction occurs, but not when an error occurs.
5430DL_5440DL_5450_TO_PDF.book 124 ページ 2005年4月12日 火曜日 午後4時49分