Konica Minolta 5430 DL 5440 DL 5450 Printer User Manual


 
Toner Cartridge / Photo Conductor Main Unit Theory of Operation
2-24
II Composition/Operation
5.2.4 Photo Conductor small amount rotation control
Ozone stagnant in areas near the Charge Corona Unit reduces sensitivity of the Photo
Conductors, causing white bands to occur in the image.
To prevent this image problem, the Photo Conductor is turned so as to allow its surface
facing the Charge Corona Unit to deviate, thereby preventing the surface sensitivity from
being reduced.
A. Photo Conductor small amount rotation timing
The number of execution sequences is determined when the post process following a
print cycle is completed. The control is executed while the Color PC Drum Motor (M2) or
Intermediate Transport Motor (M3) is in the standby state.
If the color Photo Conductors need to be turned a small amount during the monochrome
mode, the control is executed also for the color Photo Conductors.
4138to2018c4
Photo Conductor
Charge Corona Unit
5430DL_5440DL_5450_TO_PDF.book 24 ページ 2005年4月12日 火曜日 午後4時49分