Konica Minolta 5430 DL 5440 DL 5450 Printer User Manual


 
Main Unit Theory of Operation Toner Cartridge / Hopper
2-17
II Composition/Operation
4.2.4 Toner empty condition detection
A toner empty condition is detected by the LED and toner level sensor mounted on the
Toner Level Sensor Board (PWB-D) provided in the machine.
Light emitted from the LED travels through the light guiding path and is guided into the
Toner Cartridge.
The toner level sensor detects the intensity of the transmitted light guided through the
light guiding path from the inside of the Toner Cartridge. The toner level is thereby esti-
mated.
To ensure correct detection of the intensity of transmitted light by the toner level sensor, a
cleaning sheet is provided that cleans the window in the light guiding path periodically.
Detection start timing
1. When the Developing Unit is driven evenly
2. LED steady light is stabilized
3. When the above two conditions are met, the machine starts a toner empty detection
sequence. Detection control is, however, interrupted during registration correction and
gamma correction, in which it is not possible to acquire output values of the toner level
sensor.
<Empty decision>
1. A sequence is started for detecting a toner empty condition when a toner near-empty
condition is detected.
2. The machine determines that there is a toner empty condition when the toner level sen-
sor output value remains below a predetermined value and if the following event is
detected a predetermined number of consecutive times: the output value of the toner
level sensor remains a predetermined value or lower for more than a predetermined
period of time.
3. The consecutive detection count is retained even when power is turned OFF.
<Resetting empty condition>
A toner empty condition is reset when a new Toner Cartridge is detected.
4138to2012c2
4138to2012c1
LED Sensor
Light Guiding Path
Cleaning Sheet
Cleaning Sheet
5430DL_5440DL_5450_TO_PDF.book 17 ページ 2005年4月12日 火曜日 午後4時49分