Lantronix 900-422 Network Router User Manual


 
8: Setup Mode: Channel Configuration
XPress DR+ User Guide 52
Table 8-3. Flow Control Options
Flow Control Option Hex
No flow control 00
XON/XOFF flow control 01
Hardware handshake with RTS/CTS lines 02
XON/XOFF pass characters to host 05
Port Number
The setting represents the source port number in TCP connections. It is the number that
identifies the channel for remote initiating connections.
Port No (10001) ? _
The default setting for port 1 is 10001. The default setting for Port 2 is 10002. The range
is 1-65535, except for the following reserved port numbers:
Table 8-4. Reserved Port Numbers
Warning: We recommend that you not use the reserved port numbers for
this setting as incorrect operation may result.
Use Port 0 for the outgoing local port to change with each connection. The port range is
50,000 to 59,999. Each subsequent connection increments the number by 1 (it wraps
back around to 50,000).
Only use this automatic port increment feature to initiate a connection using TCP. Set the
port to a non-zero value when the unit is in a passive mode or when using UDP instead
of TCP.
Connect Mode
Connect Mode defines how the unit makes a connection, and how it reacts to incoming
connections over the network.
ConnectMode (C0) ? _
Enter Connect Mode options in hexadecimal notation.
Port Numbers Reserved for
1 – 1024 Reserved (well known ports)
9999 Telnet setup
14000-14009 Reserved for Redirector
30704 Reserved (77F0h)
30718 Reserved (77FEh)