8: Setup Mode: Channel Configuration
XPress DR+ User Guide 59
Send the Escape Sequence (+++) in Modem Mode
Send ‘+++’ in Modem Mode (Y) ? _
Disable or enable the unit's ability to send the escape sequence. The default is Y (Yes)
(send the escape sequence).
Auto Increment Source Port
Auto increment source port (N) ? _
Y (Yes) auto increments the source port. The XPress DR+ increments the port number
used with each new connection.
Remote IP Address
This is the destination IP address used with an outgoing connection.
Remote IP Address : ( 0) ( 0) ( 0) ( 0)_
Note: This option does not display when Hostlist is enabled from the
ConnectMode prompt (see Connect Mode on page 52 for more information).
Remote Port
You must set the remote TCP port number for the unit to make outgoing connections.
This parameter defines the port number on the target host to which a connection is
attempted.
Remote Port ( 0) ? _
To connect an ASCII terminal to a host using the unit for login purposes, use the remote
port number 23 (Internet standard port number for Telnet services).
Note: This option does not display when Hostlist is enabled from the
ConnectMode prompt (see Connect Mode on page 52 for more information).
DisConnMode
This setting determines the conditions under which the unit will cause a network
connection to terminate.
DisConnMode ( 0) ? _
Notes:
In DisConnMode (Disconnect Mode), DTR drop either drops the connection or is
ignored.
Note: All bit positions in the table that are blank represent “don’t care” bits, for
that particular option, which can be set to either a 0 or 1 value.