9: Setup Mode: Advanced Settings
XPress DR+ User Guide 64
ARP Cache timeout in seconds
Whenever the unit communicates with another device on the network, it adds an entry
into its ARP table. The ARP Cache timeout option allows you to define how many
seconds (1-600) the unit will wait before timing out this table.
ARP Cache timeout in s (1s – 65s; 0s=disable): (600)? _
Disable Monitor Mode at bootup
This option allows you to disable all entries into Monitor Mode during startup, except for
the xxx sequence. This prevents entry using yyy, zzz, xx1, and yy1 key sequences (only
during the bootup sequence). The default setting for Monitor Mode at bootup is N (No).
(See 11: Monitor Mode.)
Disable Monitor Mode @ bootup (N) ? _
HTTP Port Number
This option allows the configuration of the web server port number. The valid range is
1-65535. The default HTTP port number is 80.
HTTP Port Number : (80) ? _
MTU Size
The Maximum Transmission Unit (MTU) is the largest physical packet size a network can
transmit for TCP and UDP. Enter between 512 and 1400 bytes. The default setting is
1400 bytes.
MTU Size: (1400) ? _
Enable alternate MAC
If necessary, enable the alternate MAC address (if specified in the OEM setup record).
Enable alternate MAC (N) ? _
Security Settings (Option 6)
You can change security settings by means of Telnet or serial connections only, not on
the Web-Manager. We recommend that you set security over the dedicated network or
over the serial setup to prevent eavesdropping.
Caution: Disabling both Telnet Setup and Port 77FE will prevent users from
accessing Setup Mode from the network. Disabling Port 77FE also disables the
Web from configuring the device.
Select 6 to configure security settings.