Lantronix EDS4100 Server User Manual


 
7: Network, Line, Tunnel, and Terminal Settings
EDS Device Servers User Guide 69
Tunnel – Packing Mode Page
Tunnel – Packing
Mode Page
Settings
Description
Mode Select the method used to pack data. Choices are:
Disabled = default packing algorithm. (default)
Timeout = data is sent after the timeout elapses.
Send Character = data is sent when the send character is read on
the serial line.
Timeout Enter the maximum number of milliseconds to wait before sending
queued data across the network. Default is 1000 milliseconds.
Threshold Enter the queued data limit that, when reached, immediately sends
queued data to the network. Default is 512 bytes.
Send Character Enter the send character. When this character is read on the serial
line, it forces the queued data to be sent immediately. Default is
<none>.
Trailing Character Enter the trailing character. This character is inserted into the
outgoing data stream immediately after the send character. Default is
<none>.
Tunnel – Modem Emulation Page
A tunnel in connect mode can be initiated using modem commands incoming from the
serial line. If you click Modem Emulation at the top of one of the Tunnel pages, the
Tunnel – Modem Emulation page displays. Here you can select modem emulation
settings for the tunnel selected at the top of the page. For more information about modem
emulation, see Modem Emulation on page 164.Tunnel – Modem Emulation Page