4: Configuration Using Web Manager
UDS2100 User Guide 26
Monitor Mode @ Bootup Select Disable to disable entry into the monitor mode
using the yyy or xx1 key sequence at startup. This field
prevents the unit from entering monitor mode by
interpreting the stream of characters that are received
during the device server's initialization at startup. The
default setting is Enable.
HTTP Server Port This option allows the configuration of the web server
port number. The valid range is 1-65535. The default
setting is 80.
MTU Size The Maximum Transmission Unit (MTU) is the largest
physical packet size a network can transmit for TCP and
UDP. Enter between 512 and 1400 bytes. The default
setting is 1400 bytes.
3. When you are finished, click the OK button.
4. On the main menu, click Apply Settings.
Host List Configuration
The UDS2100 scrolls through the host list until it connects to a device listed in the
host list table. After a successful connection, the unit stops trying to connect to any
others. If this connection fails, the unit continues to scroll through the table until the
next successful connection.
The host list supports a minimum of 1 and a maximum of 12 entries. Each entry
contains an IP address and a port number.
Note: The host list is disabled for Manual and Modem Mode. The unit does
not accept a data connection from a remote device when the hostlist option is
enabled.
To configure the host list:
1. On the main menu, click Hostlist.