7: Setup Mode: Channel Configuration
UDS2100 User Guide 46
If a partial IP address is presented in a command string, it is
interpreted to be the least significant bytes of the IP address
and uses the internally stored remote IP address to provide
the most significant bytes of the IP address. If the IP
address entered is 0.0.0.0/0, the device server enters
Monitor Mode.
For example, if the remote IP address already configured in
the unit is 129.1.2.3, then an example command string
would be C3/7. (This would connect to 129.1.2.3 and port 7.)
You may also use a different ending for the connection
string. For example, C50.1/23 would connect you to
129.1.50.1 and port 23.
Figure 7-3. Manual Connection Address Example
Command String Result if remote IP is 129.1.2.3 and remote port is 1234
C121.2.4.5/1
Complete override; connection is started with host 121.2.4.5,
port 1.
C5 Connects to 129.1.2.5, port 1234.
C28.10/12 Connects to 129.1.28.10, port 12.
C0.0.0.0/0 Enters Monitor Mode.
Autostart (Automatic
Connection)
If you enable Autostart, the unit automatically connects to
the remote IP address and remote port specified when the
firmware starts.
Hostlist If you enable this option, the device server scrolls through
the hostlist until it connects to a device listed in the hostlist
table. Once it connects, the unit stops trying to connect to
any others. If this connection fails, the unit continues to
scroll through the table until it is able to connect to another
IP in the hostlist. Hostlist supports a minimum of 1 and a
maximum of 12 entries. Each entry contains the IP address
and the port number.
The hostlist is disabled for Manual and Modem Modes. The
unit does not accept a data connection from a remote
device when the hostlist option is enabled.