8: Setup Mode: Advanced Settings
UDS2100 User Guide 57
Security Settings (Option 6)
You can change security settings by means of Telnet or serial connections only, not
on the Web Manager. We recommend that you set security over the dedicated
network or over the serial setup to prevent eavesdropping.
Caution: Disabling both Telnet Setup and Port 77FE will prevent users
from accessing the setup menu from the network. Disabling Port 77FE
also disables the Web Manager from configuring the device.
Select 7 to configure security settings.
Figure 8-2. Security Settings
Disable SNMP
This setting allows you to disable the SNMP protocol on the unit for security reasons.
The default setting is N (No).
Disable SNMP (N) ? _
SNMP Community Name
The SNMP Community Name is a required field for NMS to read or write to a device.
Enter a string of 1 to 13 characters. The default setting is public.
SNMP Community Name (public): _
Disable Telnet Setup
Note: If you choose to disable this option, keep in mind that disabling both
Telnet Setup and Port 77FE will prevent users from accessing the setup
menu from the network.
This setting defaults to the N (No) option. The Y (Yes) option disables access to
Setup Mode by Telnet (port 9999). It only allows access locally using the web pages
and the serial port of the unit.
Disable Telnet Setup (N) ? _