10: Monitor Mode
UDS2100 User Guide 65
Table 10-1. Monitor Mode Commands
Command Command Name Function
VS x.x.x.x Version Queries software header record (16 bytes) of
unit with IP address x.x.x.x.
GC x.x.x.x Get Configuration Gets configuration of unit with IP address
x.x.x.x as hex records (120 bytes).
SC x.x.x.x Send Configuration Sets configuration of unit with IP address
x.x.x.x from hex records.
PI x.x.x.x Ping Pings unit with IP address x.x.x.x to check
device status.
AT ARP Table Shows the unit’s ARP table entries.
TT TCP Connection
Table
Shows all incoming and outgoing TCP
connections.
NC Network
Connection
Shows the unit’s IP configuration.
RS Reset Resets the unit’s power.
QU Quit Exits diagnostics mode.
G0, G1, ....,Ge, Gf Get configuration
from memory page
Gets a memory page of configuration
information from the device.
S0, S1,...,Se, Sf Set configuration to
memory page
Sets a memory page of configuration
information on the device.
GM Get MAC address Shows the unit's 6-byte MAC address.
SS Set Security record Sets the Security record without the encryption
key and length parameters. The entire record
must still be written, but the encryption-specific
bytes do not need to be provided (they can be
null since they are not overwritten).
Note: Entering any of the commands listed above generates one of the
following command response codes:
Table 7-2. Command Response Codes
Response Meaning
0> OK; no error
1> No answer from remote device
2> Cannot reach remote device or no
answer
8> Wrong parameter(s)
9> Invalid command