Diagnostic Error Code FRU/Action
011-196-XXX Serial port test halt, error threshold exceeded
1. Press F3 to review the log le.
2. Restart the test to reset the log le.
011-197-XXX Serial port test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 39
.
2. Re-run test
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
011-198-XXX Serial port test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 39
.
2. Flash the system and re-test. See “Updating
(ashing) the BIOS” on page 165.
3. Go to “Undetermined problems” on page 67.
011-199-XXX Serial port test failed, cause unknown 1. Go to “Undetermined problems” on page 67.
2. Flash the system and re-test. See “Updating
(ashing) the BIOS” on page 165.
3. Replace component under function test.
011-2XX-XXX Serial port signal failure
1. External serial device
2. System board
014-000-XXX Parallel port Interface Test Passed
No action
014-001-XXX Parallel port Presence
1. Remove external parallel device, if present.
2. Run the Setup Utility program, enable port
3. System board
014-002-XXX 014-003-XXX Parallel port Timeout/Parity
error
System board
014-013-XXX 014-014-XXX Parallel port Control
Signal/Loopback test failure
System board
014-015-XXX Parallel port External Loopback failure
1. Wrap plug
2. System board
014-027-XXX Parallel port Conguration/Setup error 1. Run the Setup Utility program, enable port
2. Flash the system. See “Updating (ashing) the
BIOS” on page 165.
3. System board
014-03X-XXX 014-04X-XXX Parallel port failure
System board
014-195-XXX Parallel port Test aborted by user
Information only Restart the test, if necessary.
014-196-XXX Parallel port test halt, error threshold
exceeded
1. Press F3 to review the log le.
2. Restart the test to reset the log le.
52 Hardware Maintenance Manual