67
Operator panel codes
Memory full
Short paper
Light sequence:
• Continue—On
• Ready—On
• Toner Low/Replace PC Kit—On
• Error—On
What this light sequence means:
The printer is processing data, but the memory used to store pages is full.
What you can do:
• Press Continue to clear the message and continue printing the job
(the job may not print correctly).
• Press and release Cancel to cancel the print job.
• Press and hold Cancel to reset the printer.
• To avoid this error in the future:
– Simplify the print job. Reduce the complexity of the page by reducing
the amount of text or graphics on the page and deleting unnecessary
downloaded fonts or macros.
– Install additional printer memory (see How to add a memory card on
page 43).
Light sequence:
• Continue—On
• Ready—On
• Load Paper—On
• Error—On
What this light sequence means:
The paper length is too short to print the formatted data. This occurs when the
printer does not know the media size loaded in the tray, or there is a problem feeding
the media.
What you can do:
• Make sure the print media you loaded is large enough.
• Open the front cover, clear the paper path, and close the cover to resume
printing (see How to clear paper jams on page 28).
• Press Continue to clear the message and continue printing the job.
• Press Cancel to cancel the print job.