Lucent Technologies Network Access Module Network Card User Manual


 
Observing Boot Messages
A-4 INA Module Installation and Configuration Guide
Use Table A-2 to interpret possible diagnostic boot messages.
Table A-2 Interpreting Diagnostic Boot Messages
Field Possible Message Explanation
INA PROM N Version number of the
installed boot PROM.
Testing System Clock ERROR This error indicates a boot
failure. Record all
information to this point
and contact Lucent
technical support.
Sizing System Memory ERROR at failed
memory address.
This error indicates a boot
failure. Record all
information to this point
and contact Lucent
technical support.
CPU Type 486DX5-133 The type of CPU installed.
Starting FLASH Boot N/A N/A
Flash Memory Am29F016 4096K Nonvolatile RAM brand
name and size in kilobytes.
16384 16384 Counter for system
memory dynamic RAM
(DRAM) size. If the size
counter freezes, record all
information to this point
and contact Lucent
technical support.
Verifying Load Module Checksum Invalid Length for
Flash at RAM
address.
This error indicates a boot
failure. Record all
information to this point
and contact Lucent
technical support.
Starting Loader N/A N/A
Testing High Memory ERROR at failed
memory address
This error indicates a boot
failure. Record all
information to this point
and contact Lucent
technical support.