Lucent Technologies Network Access Module Network Card User Manual


 
A-5
Using the DS-1 Test Jacks
Using the DS-1 Test Jacks
The six test jacks provide the means to connect external test equipment to the T1/PRI
line. Table A-3 describes the functions of the individual jacks. Figure A-1 illustrates the
test jack locations. Figure A-2 shows the test jack configuration.
Setting up ACC 2188 PCI Controller
Found 16384K PCI Memory at 0x1ffff000
Testing PCI Memory block 0x20000000-
0x20ffffff ...Passed
Total of 16384K PCI Memory Ready
block alloc 425 870400
block_alloc: cpu<0> control 0028bdb0
free_count<425>
PCI memory has been
correctly set up.
PM3VT/Legend ComOS V4.15.a4. ComOS version string.
100R HV=01 FBV=00 FAV=11 FAS=01 MERLIN firmware
identification.
Found x ports 3 Number of ports found,
including C0 and C1.
Ether0 active
PCI-Master Ethernet interface found.
Running ComOS N/A If the system becomes
suspended at this point
and does not print the next
message, the configuration
nonvolatile RAM
(NVRAM) has been
corrupted. Refer to the
PortMaster Troubleshooting
Guide for instructions on
nonvolatile RAM recovery.
PortMaster Console login: N/A System is up and running.
Table A-2 Interpreting Diagnostic Boot Messages (Continued)
Field Possible Message Explanation