Resetting the Lamp Life Counter
The lamp lasts a maximum of 1,500 hours. The projector is
designed to shut off power if the lamp is used beyond this
1,500 hours. In such case, replace the lamp and reset the lamp
life counter as follows.
1. After the Lamp Life 0 Hours message appears on the
screen, power to the projector shuts off. Promptly replace
the lamp with a new one. (See Lamp Unit Replacement
pg. 36.)
2. After replacing the lamp, press either the POWER button
on the projector or the POWER ON button on the remote
controller.
The below message will appear on the screen for about
120 seconds.
3. Select Yes using the 1 and 2 buttons.
4. Press the ENTER button to reset the lamp life counter.
Note:
The lamp is very hot while lit and shortly after being turned
off. Do not touch the lamp or lamp unit while hot. Wait at
least 1 hour for the lamp to cool down before handling it.
Do not loosen any screws except those specifically
mentioned in the below procedure.
The lamp may break under excessive force or mechanical
shock.
Use only the Marantz original lamp unit LU10VPS1 (sold
separately).
How to Replace the Lamp
Preparation:
Turn off power to the projector before replacing the lamp.
After the cooling fan stops, unplug the AC power cable
and wait at least 1 hour for the lamp to cool down. Then,
replace it.
1. Press the STANDBY button on the remote controller or
the POWER button on the projector to shut off power to
the projector.
2. After the cooling fan stops, set the ON/OFF switch in the
OFF position and unplug the AC power cable.
3. Wait at least 1 hour for the projector to cool down
sufficiently.
4. Locate the lamp cover on the projector rear (see below).
Read the caution and warning labels on the cover.
PAT T.
MENU V-MUTE
ENTER
PATTERN
STANDBY POWER ON
PATTERN
ENTER
INPUT
MENU
POWER
STANDBY
ON
Lamp Unit Replacement
PAT T.
MENU V-MUTE
ENTER
PATTERN
STANDBY POWER ON
2.
3.
4.
MENUINPUTPATTERN
ENTER
POWER
STANDBY ON
2
3
4
New Lamp ?
Yes No
Lamp cover
RS-232CDVI-D INRGB IN
EXT.INT.
IN
OUT
OFF ON
1
2
TRIG.LIGHT
REMOTE
VIDEO IN
S-VIDEO INCOMPONENT VIDEO IN 1 COMPONENT VIDEO IN 2
YP
B
/C
B
P
R
/C
R
YP
B
/C
B
P
R
/C
R
CAUTION
HIGH-PRESSURE LAMP MAY EXPLODE IF IMPROPERLY
HANDLED. REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
CAUTION HOT
UNPLUG THE POWER CORD AND WAIT 60
MINUTES BEFORE CHANGING THE LAMP.
ATTENTION
LA LAMPE SOUS HAUTE PRESSION PEUT EXPLOSER
SI ELLE, N'EST PAS MANIPULEE CORRECTEMENT,
CONFIER L'OPERATION A UN PERSONNEL D'ENTRETIEN
QUALIFIE.
VORSICHT
BEI FALSCHER HANDHABUNG KANN DIE
HOCHDRUCKLAMPE EXPLODIEREN UBERLASSEN SIE
WARTUNGSARBEITEN NUR FACHPERSONAL.
ATTENTION CHAUD
DEBRANCER LE CORD ON D'ALIMENTION ET
ATENDER 60 MINUTES AVANT DE CHANGER
LAMPE.
WARNUNG HEISS
ZIEHEN SIE DEN NETZSTECKER AB UND
WARTEN SIE 60 MINUTEN BEVOR SIE DIE
GLUHLAMPE WECHSELN.
CAUTION
HIGH-PRESSURE LAMP MAY EXPLODE IF IMPROPERLY
HANDLED. REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
CAUTION HOT
UNPLUG THE POWER CORD AND WAIT 60
MINUTES BEFORE CHANGING THE LAMP.
ATTENTION
LA LAMPE SOUS HAUTE PRESSION PEUT EXPLOSER
SI ELLE, N'EST PAS MANIPULEE CORRECTEMENT,
CONFIER L'OPERATION A UN PERSONNEL D'ENTRETIEN
QUALIFIE.
VORSICHT
BEI FALSCHER HANDHABUNG KANN DIE
HOCHDRUCKLAMPE EXPLODIEREN UBERLASSEN SIE
WARTUNGSARBEITEN NUR FACHPERSONAL.
ATTENTION CHAUD
DEBRANCER LE CORD ON D'ALIMENTION ET
ATENDER 60 MINUTES AVANT DE CHANGER
LAMPE.
WARNUNG HEISS
ZIEHEN SIE DEN NETZSTECKER AB UND
WARTEN SIE 60 MINUTEN BEVOR SIE DIE
GLUHLAMPE WECHSELN.