Meridian America D-ILA 1080MF1 Projector User Manual


 
36
Numeric value
A 2-byte signed hexadecimal value is represented by a set of 4-digit (4-byte) characters. The range
that can be specified is from 8000h to 7FFFh
ON/OFF
Shows the status (ON or OFF) of the unit, such as POWER and HIDE.
Character Hex Meaning
0 30 OFF
1 31 ON
Special parameters
Operation mode parameters
Character Hex Meaning
0000 30h 30h 30h 30h Standby mode
0001 30h 30h 30h 31h Operate mode
0002 30h 30h 30h 32h Cool down mode
0004 30h 30h 30h 34h Emergency mode (Not covered in this document)
3 External control command table
Function Command
epyTataDRequest
Operate mode ELSE Numeric Value ON/OFF Special Data
Operate U0F O
Hide U00 O O
Left/Right Reversal U17 O O
Top/Bottom
Inversion
U18 O O
Operation Mode Z03 O O O
Operation mode: Only Request command is possible