METRObility Optical Systems R380-SS Network Card User Manual


 
28 User Guide
Singlemode Fiber Optic Plug-in (O211-70)
Connector _____________________________________________________LC
Wavelength _______________________________________________ 1550 nm
Data Rate ____________________________________ 1.06 Gbps to 1.25 Gbps
RX Input Sensitivity ___ -24 dBm (min); -26 dBm (typical); -3 dBm (saturation)
Output Power _________________________ 0 dBm to 5 dBm; 2 dBm (typical)
Typical Link Budget __________________________________________ 28 dB
Supported Link Length ___________________________________ up to 70 km
Cable Type _____________________________________ 9/125 µm singlemode
Singlemode Fiber Optic Plug-in (O211-1A)
Connector _____________________________________________________LC
Wavelength _______________________________________________ 1550 nm
Data Rate ____________________________________ 1.06 Gbps to 1.25 Gbps
RX Input Sensitivity ___ -32 dBm (min); -34 dBm (typical); -3 dBm (saturation)
Output Power _________________________ 0 dBm to 5 dBm; 2 dBm (typical)
Typical Link Budget __________________________________________ 36 dB
Supported Link Length __________________________________ up to 100 km
Cable Type _____________________________________ 9/125 µm singlemode
Singlemode Fiber Optic Plug-in (O221-10)
Connector _____________________________________________________LC
Wavelength _______________________________________________ 1310 nm
Data Rate ___________________________________ 1.06 Gbps to 2.125 Gbps
RX Input Sensitivity ____-21 dBm (min); -23 dBm (typical); 0 dBm (saturation)
Output Power ______________________-9.5 dBm to -3 dBm; -6 dBm (typical)
Typical Link Budget __________________________________________ 17 dB
Supported Link Length ___________________________________ up to 10 km
Cable Type _____________________________________ 9/125 µm singlemode
Singlemode Fiber Optic Plug-in (O281-40)
Connector _____________________________________________________LC
Wavelength _______________________________________________ 1310 nm
Data Rate ____________________________________ 125 Mbps to 155 Mbps
RX Input Sensitivity __ -34 dBm (min); -36 dBm (typical); -10 dBm (saturation)
Output Power ______________________ -5 dBm to 0 dBm; -2.5 dBm (typical)
Typical Link Budget _________________________________________ 33.5 dB
Supported Link Length ___________________________________ up to 40 km
Cable Type _____________________________________ 9/125 µm singlemode