Singlemode Fiber Optic Plug-in (O281-80)
Connector _____________________________________________________LC
Wavelength _______________________________________________ 1550 nm
Data Rate ____________________________________ 125 Mbps to 155 Mbps
RX Input Sensitivity __ -34 dBm (min); -36 dBm (typical); -10 dBm (saturation)
Output Power ______________________ -5 dBm to 0 dBm; -2.5 dBm (typical)
Typical Link Budget _________________________________________ 33.5 dB
Supported Link Length ___________________________________ up to 80 km
Cable Type _____________________________________9/125 µm singlemode
Singlemode Fiber Optic Plug-in (O283-20)
Connector _____________________________________________________LC
Wavelength _______________________________________________ 1310 nm
Data Rate _____________________________________ 45 Mbps to 155 Mbps
RX Input Sensitivity ___ -28 dBm (min); -32 dBm (typical); -8 dBm (saturation)
Output Power ____________________ -15 dBm to -8 dBm; -11.5 dBm (typical)
Typical Link Budget _________________________________________ 20.5 dB
Supported Link Length ___________________________________ up to 20 km
Cable Type _____________________________________9/125 µm singlemode
Singlemode Fiber Optic Plug-in (O293-20)
Connector _____________________________________________________LC
Wavelength _______________________________________________ 1310 nm
Data Rate ____________________________________ 125 Mbps to 622 Mbps
RX Input Sensitivity _ -28 dBm (min); -30.5 dBm (typical); -8 dBm (saturation)
Output Power ____________________ -15 dBm to -8 dBm; -11.5 dBm (typical)
Typical Link Budget __________________________________________ 19 dB
Supported Link Length ___________________________________ up to 20 km
Cable Type _____________________________________9/125 µm singlemode
Singlemode Fiber Optic Plug-in (O2A3-10)
Connector _____________________________________________________LC
Wavelength _______________________________________________ 1310 nm
Data Rate ____________________________________ 155 Mbps to 2.67 Gbps
RX Input Sensitivity ____-20 dBm (min); -22 dBm (typical); 0 dBm (saturation)
Output Power ______________________ -10 dBm to -3 dBm; -6 dBm (typical)
Typical Link Budget __________________________________________ 16 dB
Supported Link Length ___________________________________ up to 10 km
Cable Type _____________________________________9/125 µm singlemode