METRObility Optical Systems R380-SS Network Card User Manual


 
30 User Guide
Singlemode Fiber Optic Plug-in (O411-80-31 to -45) for CWDM
Connector _____________________________________________________LC
Wavelength __________________________________ (see tables on next page)
Data Rate ____________________________________ 1.06 Gbps to 1.25 Gbps
RX Input Sensitivity ____-24 dBm (min); -26 dBm (typical); 0 dBm (saturation)
Output Power _________________________ 0 dBm to 5 dBm; 2 dBm (typical)
Typical Link Budget __________________________________________ 28 dB
Supported Link Length ___________________________________ up to 80 km
Cable Type _____________________________________ 9/125 µm singlemode
Singlemode Fiber Optic Plug-in (O411-80-47 to -61) for CWDM
Connector _____________________________________________________LC
Wavelength __________________________________ (see tables on next page)
Data Rate ____________________________________ 1.06 Gbps to 1.25 Gbps
RX Input Sensitivity ____-23 dBm (min); -25 dBm (typical); 0 dBm (saturation)
Output Power _________________________ 0 dBm to 5 dBm; 2 dBm (typical)
Typical Link Budget __________________________________________ 27 dB
Supported Link Length ___________________________________ up to 80 km
Cable Type _____________________________________ 9/125 µm singlemode
Singlemode Fiber Optic Plug-in (O413-40-xx) for CWDM
Connector _____________________________________________________LC
Wavelength __________________________________ (see tables on next page)
Data Rate _____________________________________ 155 Mbps to 2.7 Gbps
RX Input Sensitivity ____-20 dBm (min); -22 dBm (typical); 0 dBm (saturation)
Output Power _____________________ 0 dBm to +4 dBm; +1.5 dBm (typical)
Typical Link Budget _________________________________________ 23.5 dB
Supported Link Length ___________________________________ up to 40 km
Cable Type _____________________________________ 9/125 µm singlemode
Singlemode Fiber Optic Plug-in (O413-80-xx) for CWDM
Connector _____________________________________________________LC
Wavelength __________________________________ (see tables on next page)
Data Rate _____________________________________ 155 Mbps to 2.7 Gbps
RX Input Sensitivity ___ -30 dBm (min); -32 dBm (typical); -8 dBm (saturation)
Output Power _____________________ 0 dBm to +4 dBm; +1.5 dBm (typical)
Typical Link Budget _________________________________________ 33.5 dB
Supported Link Length ___________________________________ up to 80 km
Cable Type _____________________________________ 9/125 µm singlemode