MGE UPS Systems EX 7 RT 3:1 Power Supply User Manual


 
34007724EN/AA - Page 17
BY
PASS
NORMAL
Card Settings
RS232 Download
66074
UPS
data
Reset
100 10
1 2
ON
ETHERNET
RS232
IP=
MAC=00E0D8FF855E
Installation of communication cards (optional, standard with the Network Pack version)
It is not necessary to shut down the UPS to
install the communication card:
1 - Remove the slot cover secured by two
screws.
2 - Insert the card 1 into the slot.
3 - Secure the card with both screws.
Communication card.
1
2. Installation
Signal:
- activation voltage: 5 V DC to 27 V DC.
- current: 10 mA max.
Remote Power Off communication port 3
5 V DC to 27 V DC
Used in conjunction with the optional EPO battery module, this port enables total isolation of all power sources connected
to the UPS in case of emergency (the cable is not provided).
Remote power off contact normally open Remote power off contact normally closed
5 V DC to 27 V DC
RJ11
5432
1
6
5432
1
6
RJ11