8. Measure the width of loss for the test pattern
printed on the back of the test page.
NOTE
Do not measure from the back of the test pat-
tern.
Standard width (a):
3.0 mm ± 1.0 mm
If the measured width of loss does not meet
its standard width, click and in the
lower-right corner of the screen to adjust the
width. Print another test page and check the
printed image.
9. Adjust the paper reference positions for the
2nd, 3rd and 4th drawers in the same way
(by repeating steps 6 through 8).
NOTE
The 4th drawer is only available if two optional
paper feed units are installed.
4657U006AA
Paper Exit
Direction