Monarch 9460 Printer User Manual


 
5-80 Command Reference
SYSSET
Purpose Sets the printer’s default parameters.
Syntax SYSSET
function
,
parameter1
,
parameter2
Process The SYSSET command sets the
function
parameter with the
parameter1
value, and
if applicable, the
parameter2
value. If parameter1 and parameter2 are both buffer
fields, they must be numeric. If they are a constant, precede it with a number sign
(#) except where noted.
The
function, parameter1, and parameter2
fields can be one of the following:
Function/Description Parameter1 Parameter2
PROMPTS
The language to use for
the printer’s prompts.
1 (English)
2, 3 (Downloaded
Foreign)
4 (Alternate)
n/a
BAUDRATE
The rate for data
transfers.
19.2K, 9600, 4800,
2400, 1200
(Do Not precede with #)
n/a
FLOWCONTROL
The flow control for
data transfers.
NONE, DTR, RTSCTS,
XONOFF (Do Not
enclose in quotes)
n/a
PARITY
The parity for data
transfers.
ODD, EVEN, MARK,
SPACE, None (Do Not
enclose in quotes)
n/a
STATUSPOLLING
Perform status polling
during data transfers.
0 (Disabled)
1 (Enabled)
n/a
STOPBIT
The number of stop bits
for data transfers.
1 or 2 n/a
DATABITS
The number if data bits
for data transfers.
7 or 8 n/a
ONDEMAND
Print labels only when
requested.
0 (Disabled)
1 (Enabled)
n/a
BACKLIGHT
Enables or disables this
parameter. If enabled,
sets the number of
seconds without activity
before the backlight
turns off automatically.
0 (Disabled)
1 (Enabled)
2-480 (Timeout)
n/a