Moxa Technologies 405A Switch User Manual


 
EDS-408A/405A Series User’s Manual Featured Functions
3-14
The SNMP page can be configured. A more detailed explanation of each parameter follows:
SNMP Read/Write Settings
SNMP Versions
Setting Description Factory Default
V1, V2c, V3
Select SNMP protocol versions V1, V2c,
V3 to manage the switch
V1, V2c
Select SNMP protocol versions V1, V2c to
manage the switch
V3 only
Select only SNMP protocol version V3 to
manage the switch
V1, V2c
V1, V2c Read Community
Setting Description Factory Default
V1, V2c Read
Community
Use a community string match for
authentication. This means that the SNMP
agent accesses all objects with read-only
permissions using the community string
public.
public
Maximum 30 characters
V1, V2c Write/Read Community
Setting Description Factory Default
V1, V2c
Read/Write
Community
Uses a community string match for
authentication, which means that SNMP
servers access all objects with read/write
permissions using the community string
private.
private
Maximum 30 characters
For SNMP V3, there are two levels of privilege for different accounts to access the EDS. Admin
privilege allows access, and authorization to read and write the MIB file. User privilege only
allows reading the MIB file, but does not authorize writing.