Moxa Technologies CP-114 Series Network Card User Manual


 
3-20 Industio CP-114 User's Manual
Loading Driver
Having completed the setup, you can load the driver, "BIN\DP-DRV.EXE", at the DOS prompt.
The driver will detect the Industio CP-114 Series board automatically. If the board(s) is(are)
detected, a message similar to below will show:
Smartio/Industio Family DOS driver Version 1.1
Setup driver….
CP-114 series (Bus=0, Dev=11): O.K.!
Device driver setup O.K.
It means the Industio CP-114 Series driver is installed properly. At this point, you are ready to
execute application that supports API-232 functions, or start developing applications using API-232
library.
If something went wrong, for instance, the board does not match the configuration or the board is
missing, the screen will show a message like:
Smartio/Industio Family DOS driver Version 1.1
Setup driver….
CP-114 series (Bus=0, Dev=11): Board not Found.!
Setup none port !!
It means the Industio CP-114 Series driver is not installed properly. Please refer to chapter,
“Troubleshooting”, for possible reasons and solutions.
Unloading Driver
To unload (release) the Industio CP-114 Series driver from memory, type "DP-DRV/Q" at the DOS