39
Chapter4SelfCalibration
●
Setting Adjustment Target
Set the calibration targets for SelfCalibration.
Procedure
1. Choose “SelfCalibration” from the Adjustment menu, and press
.
2. Choose “Settings” from “SelfCalibration”, and press
.
3. Choose “Target” from “Settings”, and press
.
4. Use
or to select the mode to change, and press .
The target setting menu appears.
5. Use or to select the items to change, and press .
Settings Adjustable Range Setting
Brightness 30cd/m
2
to200cd/m
2
Setthebrightnessofthemonitorusing
thebrightnessvalue(cd/m
2
).
WhitePoint White(x)/White(y) 0.2400-0.4500
*1
SetthemonitorWhitePointusingthe
colorcoordinateorTemperature.
Temperature 4000K-10000K
(100KUnit)
*2
ColorGamut ColorGamut Native Donotadjustthecolorgamut.
User Adjustthecolorgamut.
ForeachofRed/Green/
Blue
0.0000-1.0000 Tocalibratethemonitorcolor
reproductiongamut,setthecolor
coordinatesforred,green,andblue.
Clipping On/Off Thisfunctionallowsyoutodisplaythe
monitorwiththecolorsbasedonthe
speciedcolorgamut.
(“Tosetclipping”(page22))
Gamma 1.6-2.7
(0.1Unit)
*3
Setthemonitorgammavalues.
*1
Whenthecolorcoordinatesareset,thetemperaturechangesto“User”.
*2
Whenthetemperatureisset,thexandycoordinatesofthewhitepointaresetautomatically.
*3
Thesebecome“Fixed”whencalibratingwithColorNavigator.
6. Use or for adjustment.
7. Press
to exit.
The calibration targets are set.
Attention
• Only set the color gamut calibration when the target color range is precisely known.
• If ColorNavigator was used to calibrate the grey balance, do not change the gamma setting values.
4-2. Executing SelfCalibration
Procedure
1. Choose “SelfCalibration” from the Adjustment menu, and press
.
2. Choose “Execute” from “SelfCalibration”, and press
.
The built-in calibration sensor is activated, and SelfCalibration is executed.
Attention
• To execute SelfCalibration, it is necessary to set the calibration details. For more information, see “4-1. Setting
Calibration Details” (page 36).
• After selecting “Execute”, aging may be executed before the built-in calibration sensor is executed.