National Instruments 800 Series Switch User Manual


 
Chapter 3 VXIpc 800 Series Configuration and Installation
© National Instruments Corporation 3-3 VXIpc 800 Series User Manual
Table 3-1 lists the factory-default settings and options for the onboard
jumpers and switches.
Table 3-1. VXIpc 800 Series Hardware Default Settings
Jumper/
Switch
Default
Setting
Optional
Setting
W1 Supply SCSI termination
power
Disable SCSI termination
W2 Normal CMOS operation Clear CMOS
W4 LPT1 uses DMA Channel 1 LPT uses DMA Channel 3
W13 Enable automatic Slot 0
detection
Force Slot 0;
Force Non-Slot 0
S1 Enable Ethernet EEPROM
configuration
Disable Ethernet EEPROM
configuration (uses default
power on values)
S2 Enable MITE
self-configuration
Disable MITE
self-configuration
S3 Source CLK10 from
onboard oscillator
Source CLK10 from SMB
S4 Non-inverted CLK10
output
Inverted CLK10 output
S5 Receive CLK10 input from
SMB
Source CLK10 output to
SMB
S6 No termination on CLK10
input
Terminate CLK10 input
to 50
S7 No termination on external
trigger input
Terminate external trigger
input to 50
S8 GPIB uses IRQ11 GPIB uses IRQ5
S9 MITE user configuration MITE factory configuration