Chapter 3 VXIpc 800 Series Configuration and Installation
© National Instruments Corporation 3-3 VXIpc 800 Series User Manual
Table 3-1 lists the factory-default settings and options for the onboard
jumpers and switches.
Table 3-1. VXIpc 800 Series Hardware Default Settings
Jumper/
Switch
Default
Setting
Optional
Setting
W1 Supply SCSI termination
power
Disable SCSI termination
W2 Normal CMOS operation Clear CMOS
W4 LPT1 uses DMA Channel 1 LPT uses DMA Channel 3
W13 Enable automatic Slot 0
detection
Force Slot 0;
Force Non-Slot 0
S1 Enable Ethernet EEPROM
configuration
Disable Ethernet EEPROM
configuration (uses default
power on values)
S2 Enable MITE
self-configuration
Disable MITE
self-configuration
S3 Source CLK10 from
onboard oscillator
Source CLK10 from SMB
S4 Non-inverted CLK10
output
Inverted CLK10 output
S5 Receive CLK10 input from
SMB
Source CLK10 output to
SMB
S6 No termination on CLK10
input
Terminate CLK10 input
to 50 Ω
S7 No termination on external
trigger input
Terminate external trigger
input to 50 Ω
S8 GPIB uses IRQ11 GPIB uses IRQ5
S9 MITE user configuration MITE factory configuration