National Instruments 800 Series Switch User Manual


 
Appendix A Specifications
© National Instruments Corporation A-3 VXIpc 800 Series User Manual
Environmental
Note: Random vibration profiles were developed in accordance with
MIL-T-28800E and MIL-STD-810E Method 514. Test levels exceed
those recommended in MIL-STD-810E for Category 1 (Basic
Transportation, Figures 514.4-1 through 514.4-3). Test report
available upon request.
VMEbus Capability Codes
Characteristic Specification
Temperature 0° to 55° C Operating;
-20° to 70° C Storage
Relative
Humidity
0% to 95% Noncondensing, Operating;
0% to 95% Noncondensing, Storage
EMI FCC Class A Verified, EC Verified
Vibration Operational: 5 to 500 Hz, 0.31 g, 3 axes
Non-operational: 5 to 500 Hz, 2.5 g, 3 axes
Functional Shock MIL-T-28800E Class 3 (per Section 4.5.5.4.1)
Half-Sine Shock Pulse (11 ms duration, 30 g peak,
3 shocks per face)
Capability Code Description
A32, A24, A16 (master) VMEbus master A32, A24, and A16
addressing
A32, A24, A16 (slave) VMEbus slave A32, A24, and A16
addressing
D64, D32, D16,
D08(EO) (master)
VMEbus master D64, D32, D16, and
D08 data sizes
D64, D32, D16,
D08(EO) (slave)
VMEbus slave D64, D32, D16, and
D08 data sizes